A low voltage ride through measure suitable for doubly-fed wind power generators
编号:13 访问权限:仅限参会人 更新:2021-12-03 10:27:40 浏览:569次 张贴报告

报告开始:2021年12月17日 14:35(Asia/Shanghai)

报告时间:5min

所在会场:[Z] Poster Session [Z1] Poster Session 1: Renewable energy system

暂无文件

摘要
Grid-connected wind power generators in wind farms require low voltage ride-through functions to meet grid failures, especially uninterrupted operation under grid voltage sag failures. Therefore, aiming at the shortcomings of conventional Crowbar, this article designs a protection scheme based on the combination of Crowbar and DC-Chopper. A wind farm simulation model was established, and the short-circuit current output characteristics of a wind turbine with low voltage ride through capability (LVRT) under asymmetric fault and symmetric fault conditions were simulated. And verified its optimized performance.
关键词
DFIG; Crowbar protection; DC-Chopper circuit; Symmetrical short circuit fault; Asymmetric short circuit fault;