Design of External UHF Sensor for Partial Discharge of Power Transformer
编号:230 访问权限:仅限参会人 更新:2021-12-03 10:50:24 浏览:527次 口头报告

报告开始:2021年12月17日 10:00(Asia/Shanghai)

报告时间:15min

所在会场:[D] High voltage and insulation technology [D5] Session 28

视频 无权播放 演示文件

提示:该报告下的文件权限为仅限参会人,您尚未登录,暂时无法查看。

摘要
 AbstractUltra-high frequency (UHF) method is one of the main methods of detecting partial discharge (PD) in transformer. Common cases, the built-in sensor of the oil drain valve is used during the maintenance of the transformer, or the sensor is preset by the dielectric window at the side of the tank when the transformer out of the site. However, for the transported transformer, it is difficult to apply those ways. Aiming at the disadvantages of the installation method of the oil drain valve type and dielectric window type sensor, according to the characteristics of the transformer partial discharge UHF electromagnetic (EM) wave that can leak out of the tank gap, a UHF type sensor was designed for the detection of partial discharge at the gap of the transformer tank. First, based on the simplification of the internal structures of the transformer, the finite difference time domain method (FDTD) was used to build the transformer model, and the propagation characteristics of the electromagnetic wave signal excited by the partial discharge source inside the transformer leaking out of the external space through the gap was simulated, and the electrical field structure was further analyzed. Secondly, the deformable planar monopole antenna is designed according to the slot structure and internal electric field structure of the oil tank, and the geometric parameters of the antenna are optimized. Finally, the designed sensor is used to detect PD in the gap of FDTD model. The simulation results show that the UHF electromagnetic wave signal leaked through the gap of the transformer tank has a certain attenuation, and the sensor can effectively detect the partial discharge signal at the gap.
关键词
power transformer,partial discharge,fuel tank gap,UHF sensor
报告人
Dongchen Liu
North China Electric Power University

稿件作者
Dongchen Liu North China Electric Power University
Anxu Guan North China Electric Power University
Shusheng Zheng North China Electric Power University
Yan Zhao North China Electric Power University
Zhong Zheng North China Electric Power University
Aixu Zhong North China Electric Power University
发表评论
验证码 看不清楚,更换一张
全部评论
重要日期
  • 会议日期

    07月11日

    2023

    08月18日

    2023

  • 11月10日 2021

    初稿截稿日期

  • 12月10日 2021

    注册截止日期

  • 12月11日 2021

    报告提交截止日期

主办单位
IEEE IAS
承办单位
IEEE IAS Student Chapter of Southwest Jiaotong University (SWJTU)
IEEE IAS Student Chapter of Huazhong University of Science and Technology (HUST)
IEEE PELS (Power Electronics Society) Student Chapter of HUST
移动端
在手机上打开
小程序
打开微信小程序
客服
扫码或点此咨询