The Saturated Inductance of the Magnetic Switch in RSD-based Pulse Circuit
编号:82 访问权限:仅限参会人 更新:2025-10-11 22:48:20 浏览:2次 张贴报告

报告开始:暂无开始时间(Asia/Shanghai)

报告时间:暂无持续时间

所在会场:[暂无会议] [暂无会议段]

暂无文件

摘要
Reversely switched dynistor (RSD) is a semiconductor switch which is suitable to be used in pulsed power systems. In many trigger circuits of RSD, a magnetic switch is usually needed. In this study, the saturated inductance of the magnetic switch is simulated. In addition, the relative permeability of the magnetic switch in the forward saturation process is measured. Based on the experimental results, if H is in the range of 1000 A/m to 2000 A/m, the relative permeability should be set between 4 and 5.5. If H is in the range of 2000 A/m to 5000 A/m, the relative permeability should be set between 3 and 4.5. However, at the H of tens of kA/m, the inductance of the magnetic switch can be calculated at relative permeability is 1.
关键词
RSD,magnetic switch,saturated inductance